See how an Article 220 dwelling calculation uses floor area, circuit allowances and equipment ratings, with a bounded example of the 220.82 general-load subtotal.

YKCA Journal · Sources reviewed October 3, 2026

Explore the guide
Turn an inventory into an assessed load: Inputs; Method; Separate limits

The 16,400 VA example is a general-load subtotal, not a complete service approval.

Electrical load calculations service ↗All service guides ↗

The key decision

Breaker handles identify circuit protection, not a sum of simultaneous household demand. Ask which Article 220 method fits the project, obtain the actual load inventory, and keep the demand result separate from breaker space, equipment condition and feeder limits.

The same breaker can serve very different actual loads

A saved EV-charging discussion asks for help interpreting a load calculation and the different equipment ratings at the service. Those numbers can easily be mistaken for interchangeable measures of capacity. Start by distinguishing circuit protection, equipment ratings and calculated demand before using the panel’s breaker labels as a shortcut.

Adding every breaker number counts protective-device ratings rather than calculating the load supplied by the service. Many circuits operate well below their breaker rating, and their largest loads do not necessarily run together. A two-pole device also does not become two independent appliances merely because it occupies two positions.

A panel photo remains useful for identifying equipment and missing records. It cannot supply floor area, appliance nameplate values, installed heating options or the calculation method. Likewise, empty positions show room for compatible breakers only; they do not prove spare demand capacity.

Source: Load Calculation Help

Identify the code edition and the applicable method

California’s 2025 Electrical Code took effect January 1, 2026 and adopts the 2023 National Electrical Code with California amendments. Confirm the edition and local requirements applicable to the permit. Article 220 contains feeder and service calculation methods; section 220.82 is an optional dwelling-unit method with specific supply and application conditions. Section 220.83 addresses existing dwelling units, and section 220.87 permits qualifying measured-demand records for existing installations.

These methods do not share every allowance or demand factor. Ask the designer to name the selected method before interpreting the worksheet. A result from one method cannot be combined with convenient pieces of another to create an unsupported result.

Source: California Building Standards Commission: code editions and errata · Truckee: residential forms index, including the electrical load worksheet · LBNL: Characterizing electrical panel capacity, breaker space, and loads in U.S. single-family homes · Daly City: building handouts, including EMS plan review and inspection guidelines

A worked general-load subtotal explains the difference

Consider only the general-load portion of a hypothetical dwelling that qualifies for section 220.82. Assume 1,800 square feet, two small-appliance circuits, one laundry circuit and 16,100 VA of applicable appliance/nameplate loads. The floor-area allowance is 1,800 × 3 = 5,400 VA. The three circuit allowances add 3 × 1,500 = 4,500 VA. With 16,100 VA of applicable appliance loads, the subtotal is 26,000 VA.

For this portion of the optional method, the first 10,000 VA is taken at 100%, and the remaining 16,000 VA at 40%. The resulting general-load contribution is 10,000 + 6,400 = 16,400 VA. This is a calculation from identified loads and a specified demand factor; the breaker-handle sum appears nowhere in it.

This subtotal is not the complete service calculation or permission to add a circuit. Heating and cooling treatment, all applicable loads and the method’s conditions still require review. The example intentionally does not calculate EV charging, auxiliary heat or a multiunit building from a generic percentage. VA means volt-amperes.

Source: Truckee: residential forms index, including the electrical load worksheet

Read demand, space and equipment condition as separate results

Suppose the calculation supports the proposed load but there is no position for the required breaker. That is a distribution-space problem to resolve using a permitted, compatible arrangement. A subpanel may provide space, but it does not increase the upstream service rating. Conversely, unused breaker positions do not solve a demand result that exceeds the supply’s permitted capacity.

A passing numerical result also does not resolve damaged equipment, incompatible breakers or an inadequate feeder. Ask the report to identify each limitation and the work that addresses it. This prevents a broad recommendation such as “upgrade the panel” from hiding the actual reason or overlooking another needed correction.

Supply the inventory that makes the result reviewable

Provide floor area, the circuit and appliance inventory, selected new equipment specifications, existing drawings and known electrical changes. Identify removed equipment as well as additions; a gas-to-electric conversion and an electric replacement can have different net effects. State any controls on which the design will rely.

Keep the completed calculation, its code basis and assumptions with the approved scope. If a model, load or control changes later, compare the change with those assumptions before deciding whether the calculation remains applicable. The saved worksheet is useful because it explains the result, not merely because it has a passing total.

Put it into practice

A decision table to keep handy

Record to checkEvidenceDecision it supports
InputsFloor area, allowances and nameplatesRecord actual project data
MethodApplicable Article 220 calculationApply the correct demand treatment
Separate limitsService, feeder, space and conditionIdentify the work actually needed

Bring this to the conversation

Your next-step checklist

Common questions

Can I add all the breaker numbers to find the load?

No. Breaker ratings describe circuit protection. An applicable Article 220 method uses the home’s load inventory, required allowances and demand factors, or qualifying measured-demand records. Ask for the method and inputs used; breaker space and equipment condition need separate review.

Check the original guidance

Sources & review date

Primary guidance and available source excerpts reviewed October 3, 2026. Requirements and program terms can change; verify the current instructions for your property and project before committing to work.

Reader discussions behind this guide

These discussions illustrate reader problems; they are not technical instructions or a measure of how common a problem is. The guidance above draws on the primary sources listed here.